RCD S TYPE 125A 300MA,RCCB RCD ELCB,Earth Leakage Circuit Breaker RCCB125A 300MA

Home > Products > Circuit Breaker > Residual Current Circuit Breaker > Residual Current Circuit Breaker s type 6ka up to 125A AC/A /S TYPE

Residual Current Circuit Breaker s type 6ka up to 125A AC/A /S TYPE

Share to:  
    Payment Type: L/C,T/T,D/P,Paypal
    Incoterm: FOB
    Min. Order: 100 Bag/Bags
    Delivery Time: 15 Days

Basic Info

Model No.: KNL5-100

Frame: 63A

Rated Limiting Short-circuit Current: 3000A

Rated Worling Current: 16;20;25;32;40;50;63A

Rated Working Voltage: 240V/415V

Sensibility: ACtype

Additional Info

Packaging: carton

Productivity: 5000PCS/DAY

Brand: Korlen

Transportation: Ocean,Land,Air

Place of Origin: Wenzhou; Zhejiang; China

Certificate: CE,CB

HS Code: 8536200000

Port: Ningbo,ShangHai

Product Description

DATA SHEET:

KNL5series Residual Current Circuit Breaker(without over-current protection) is suitable for the line of A and S 50/60Hz, voltage 240V(2pole)/415V(4pole), rated current up to 100A. When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will cut off the power rapidly to protect human safety and prevent the accident due to the current leakage. It can be used as infrequent changeover of the line in normal situation. It is applicable to industrial site, commercial site, tall building and civil house.
It complies with standard of IEC/EN61008.1 and GB16916.1.
Each phase of conductor at the Circuit Breaker passes through the zero-sequence current transformer, and the secondary side of coil connects with the electromagnetic tripper. Under normal condition, the vector sum of each phase of current passing through zero-sequence current transformer is zero. The flux of the zero-sequence current transformer is zero. And the secondary output voltage is zero and the circuit breaker doesn't zero, and the zero-sequence current transformer would produce the magnetic flux, and the secondary side of coil would output the voltage. Once the leak current increases to drive the output voltage at the secondary side to grow to certain level, the electromagnetic release would activate to drive the operation mechanism to act to break the contact that connects the power, finally to realize the leak protection.

Frame class 125A
Rated working voltage 240/415V
Rated frequency 50/60Hz
Rated working current 80,100,125A
Rated residual operating current 0.03,0.1,0.3,0.5A
Rated residual un-operating current 0.015,0.05,0.15,0.25A
Sensibility A Type,AC Type,S Type
Maximum operating time IΔn t≤0.1s , 5IΔn t≤0.04
Rated making and breaking capacity In≤50A 500A,In=63A 630A , In>63A 1500A
Limiting value of un-operating current 6In
Rated limiting short-circuit current 6000A
Pole number 2,4P
Mechanical life 6000
Electric life 4000

100A RCCB

Looking for ideal RCD S TYPE 125A 300MA Manufacturer & supplier ? We have a wide selection at great prices to help you get creative. All the RCCB RCD ELCB are quality guaranteed. We are China Origin Factory of Earth Leakage Circuit Breaker RCCB125A 300MA. If you have any question, please feel free to contact us.